Asante 10BaseT Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Vernetzung Asante 10BaseT herunter. Asante 10BaseT Installation guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - 10T Hub/24

Asanté 10T Hub/810T Hub/1210T Hub/24 for Twisted Pair Networks Installation Guide

Seite 2 - Trademarks

List of Tables Page ix Table 2-1 Power Adapter Specifications . . . . . . . . . . . . . . . . . . . . . . . . 2-2Table 3-1 Hub LED Description . .

Seite 3 - Warranty

Preface • About the 10T Hub Family on page xiv• About This Manual on page xvi• About 10BaseT on page xvii• Other Asanté 10BaseT Networking Products o

Seite 4 - Limitation of Liability

Page xiv About the 10T Hub Family The Asanté™ 10T Hub is a hardware device that lets you create high-speed Ethernet networks over ordinary, unshielde

Seite 5 - Asking for assistance

Page xv About the 10T Hub Family Features ❏ Cost effective, easy to use, plug-and-play unmanaged hub requiring no switch setting ❏ AUI port provided

Seite 6 - Tell us what you think

Page xvi About This Manual This manual is divided into four chapters and four appendices:Chapter 1, “Planning a Network Installation” on page 1-1 exp

Seite 7

Page xvii About 10BaseT About 10BaseT Twisted-pair Ethernet, as defined by the IEEE 802.3 specifications, is called 10BaseT. This is the latest develop

Seite 8

Page xviii Other Asanté 10BaseT Networking Products To connect your personal computers and other network devices to a 10T Hub, you will need a 10Base

Seite 9

1 Planning a Network Installation • Before You Start on page 1-2• Assign a Network Manager on page 1-3• Create a Network Map on page 1-4• Planning fo

Seite 10

Page 1-2 Planning a Network Installation Before You Start An efficient network that will serve your long-term needs requires thorough planning. This c

Seite 11

Page 1-3 Assign a Network Manager Assign a Network Manager A network manager initially coordinates the design and installation of the network. Once t

Seite 12 - About the 10T Hub Family

Page i Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Asanté Technolo

Seite 13 - Features

Page 1-4 Planning a Network Installation Create a Network Map A network map is a visual record of your network configuration. Create a network map by

Seite 14 - About This Manual

Page 1-5 Planning for Network Operations Planning for Network Operations Create a Network Log A network log is a record of the names of devices, loca

Seite 15 - About 10BaseT

Page 1-6 Planning a Network Installation ❏ You must use solid copper (not stranded) twisted-pair wiring. You can identify twisted-pair wire by altern

Seite 16 - Products

2 Installation • Before You Start on page 2-2• Plug and Play Installation on page 2-3• 10BaseT Station to Hub Connection on page 2-4• Connecting to T

Seite 17

Page 2-2 Installation Before You Start Before you begin the installation, check the AC voltage of the your country area. The AC power adapter used wi

Seite 18 - Before You Start

Page 2-3 Plug and Play Installation Plug and Play Installation The Asanté 10T Hubs are designed for plug and play installation. Before you connect th

Seite 19 - Assign a Network Manager

Page 2-4 Installation 10BaseT Station to Hub Connection Do the following steps to connect a 10BaseT Ethernet station to a hub. 1 Make sure the straig

Seite 20 - Create a Network Map

Page 2-5 Connecting to Thin Coaxial Cable Ethernet Connecting to Thin Coaxial Cable Ethernet Do the following steps to connect a thin Ethernet configu

Seite 21

Page 2-6 Installation ▲ Only one shared port is available on the 10T Hub/8 foreither BNC or AUI connection. This port is equippedwith two connectors:

Seite 22

Page 2-7 Connecting to Thick Coaxial Cable Ethernet Connecting to Thick Coaxial Cable Ethernet The AUI connector on the hubs can be used to connect a

Seite 23 - Installation

Page ii FCC Information This equipment is classified as a Class A computing device. Class A devices may be used only in commercial, business, or indu

Seite 24

Page 2-8 Installation Connecting Multiple Hubs for a Larger Network You have several choices when connecting networks with more than one hub: ❏ Use u

Seite 25 - Plug and Play Installation

Page 2-9 Interconnecting via the UTP Port Interconnecting via the UTP Port To interconnect multiple star networks using the UTP ports: 1 Use two, ISO

Seite 26 - Straight through cable

Page 2-10 Installation Multiple Hubs Using 10BaseT Connection Figure 2-6 below illustrates an Ethernet twisted-pair LAN that uses multiple hubs conne

Seite 27 - Ethernet

Page 2-11 Interconnecting via the BNC Port Interconnecting via the BNC Port To connect multiple hubs using the BNC Port on the hubs: 1 Connect each h

Seite 28

Page 2-12 Installation Wiring RJ21 Installations The 10T Hub12 provides an additional RJ21 connector to provide an alterna-tive way to wire the works

Seite 29

Page 2-13 Wiring RJ21 Installations Figure 2-8 Wiring on RJ45 Wall Jack to a Punchdown Block 4 Connect a network interface card or TP-MAU (if you are

Seite 30

3 Troubleshooting Your Network • Before You Start on page 3-2• Interpreting the Hub LEDs on page 3-3• Testing Your Installation on page 3-4• Common P

Seite 31

Page 3-2 Troubleshooting Your Network Before You Start Testing and monitoring your network’s status is done with the aid of the LEDs on the hub, the

Seite 32

Page 3-3 Interpreting the Hub LEDs Interpreting the Hub LEDs When you first turn on your Asanté 10T Hub, all the LEDs switch ON while the hub goes t

Seite 33 - Caution:

Page 3-4 Troubleshooting Your Network Testing Your Installation After your installed wiring is connected, you need to begin testing the instal-lation

Seite 34 - Wiring RJ21 Installations

Page iii Warranty Disclaimers Asanté Technologies, Inc. makes no other warranties, express, implied, or otherwise, regarding the 10T Hub/8, 10T Hub/1

Seite 35

Page 3-5 Common Problems Found in the Hub Common Problems Found in the Hub Link Status LED is off. Probable cause is a twisted-pair connector is not

Seite 36 - Troubleshooting Your Network

Page 3-6 Troubleshooting Your Network ❏ Other workstations connected to hub, disrupting com-muncation of workstations being brought upRemove the disr

Seite 37

Page 3-7 Diagnosing the Network Interface Card Diagnosing the Network Interface Card Most card manufacturers include some form of diagnostic software

Seite 38 - Interpreting the Hub LEDs

A Cable Wiring Diagrams • RJ45 Connector on page A-2• AUI (DB15) Connector on page A-3• Eight-Position (RJ45) Modular Cable on page A-4 10T Hub App A

Seite 39 - Testing Your Installation

Page A-2 RJ45 Connector Table A-1 RJ45 Connector Wiring DescriptionFigure A-1 RJ45 Connector Pin Symbol Function Signal Type 1 TD+ Transmit Data Plus

Seite 40

Page A-3 AUI (DB15) Connector AUI (DB15) Connector Table A-2 AUI Wiring DescriptionFigure A-2 AUI (DB15) Female Connector Pin Symbol Pairs Used 3 DO+

Seite 41 - Network Management Software

Page A-4 Eight-Position (RJ45) Modular Cable An eight-position modular cable can terminate up to four pairs of a cable; pairs 2 and pairs 3 may be re

Seite 42

Page A-5 Eight-Position (RJ45) Modular Cable Figure A-4 RJ21 Color Coding1 TD + White/Blue2 TD - Blue/White3 RD + White/Orange6 RD - Orange/White1 TD

Seite 43 - Cable Wiring Diagrams

B Mounting the Hub • Wall Mounting the Hub on page B-2

Seite 44 - RJ45 Connector

Page B-2 Wall Mounting the Hub Your hub can be used as a desktop unit or as a wall mount unit. Two keyhole slots are provided on the bottom of the hu

Seite 45 - 1413121110 9

Page x Asking for assistance To contact Asanté Technical Support:1. Please request catalog of contents.2. Download INDEX.TXT file for catalog of conte

Seite 46

C Technical Specifications

Seite 47

Page C-2 IEEE 802.3 Compliance ❏ 10BaseT (twisted-pair, UTP) ❏ 10Base2 (thin, BNC) ❏ 10Base5 (thick, AUI) 10T Hub/8 ❏ Eight 10BaseT, UTP ports. Port

Seite 48 - Mounting the Hub

Page C-3 Maximum Cable Lengths ❏ 10Base5 (thick Ethernet, AUI): 50 meters maximum to Ethernet MAU (transceiver) with shielded, twisted-pair drop cabl

Seite 49 - Wall Mounting the Hub

Index i Index Numerics 10Base5 thick Ethernet 2-710BaseTabout xivdescribed xviiusing telephone wire 1-210BaseT products, other Asanté xviii

Seite 50 - Technical Specifications

Index ii to other devices 2-3to other hubs. See connecting multiple hubsto thick Ethernet 2-7to thin Ethernet 2-5connecting multiple hubs 2-8

Seite 51

Index iii connecting workstations to hubs 2-9thin 2-5expansion, considering future 1-5 F features of 10T Hubs xvfuture expansion, considering

Seite 52

Index ivLink Status LEDs 3-3, 3-4, 3-5location, determining hub 1-6Mmanager, networkassigning 1-3responsibilities 1-3map, networkcreating 1-4as instal

Seite 53

Page -vplanningnetwork installation 1-1for network operations 1-5plug and play installation 2-3plugging in network segments 2-3portsAUI xv, 2-8, C-2BN

Seite 54

Page -vinumber of connections 2-5topologybus xviihierarchical 2-8star 1-2wiring affecting choice of 1-5TP-MAU (twisted-pair media attachment unit) 2-9

Seite 55

Page xi Tell us what you think Tell us what you think Asanté Technologies is interested in your comments/suggestions about our manuals. If you take t

Seite 56

Page v Table of Contents Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iTrademarks . . . . . .

Seite 57

Page vi Interconnecting via the BNC Port. . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11Interconnecting via the AUI Port . . . . . . . .

Seite 58

Page viii List of Figures Figure 1-1 Sample network map . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4Figure 2-1 AC Power Adapter . .

Kommentare zu diesen Handbüchern